# ESP32 API and Serial Commands
## HTTP API
Base URL while connected to the ESP32 access point:
http://192.168.4.1
## Status
### GET /status
Returns full controller status, including battery/BMS telemetry, relay states, temperature sensor states, alarms, system info, and current configuration.
Relay states use generic IDs:
relay_1
relay_2
Temperature sensors use generic IDs:
temp_1 through temp_8
## Relay Control API
GET /relay/relay_1/on
GET /relay/relay_1/off
GET /relay/relay_2/on
GET /relay/relay_2/off
Relay display names are configurable. Firmware and API clients should not assume what a relay controls.
## Configuration API
### GET /config
Returns saved configuration.
### POST /config/relay
Example:
{
"id": "relay_1",
"name": "Aux Power",
"enabled": true
}
### POST /config/bms
Example:
{
"enabled": true,
"name": "House Battery",
"address": "aa:bb:cc:dd:ee:ff",
"address_type": "public"
}
### POST /config/temp
Example:
{
"id": "temp_1",
"name": "Cabin",
"address": "",
"enabled": true
}
### POST /config/factory-reset
Clears saved configuration and restores generic defaults.
## Serial Monitor
Baud:
115200
Line ending:
Newline
## Status and Config Commands
status
config
save
factory reset
## Log Level Commands
log quiet
log info
log debug
## Relay Control Commands
relay 1 on
relay 1 off
relay 2 on
relay 2 off
## Relay Configuration Commands
relayname 1 Aux Power
relayname 2 Accessory Power
Run `save` after changing names.
## Temperature Sensor Configuration Commands
tempname 1 Cabin
tempname 2 Outside Air
Run `save` after changing names.
## BMS Configuration Commands
bmsname House Battery
bmsaddr aa:bb:cc:dd:ee:ff
Run `save` after changing BMS config manually.
## BMS Setup Mode Commands
enter setup
scan ble
select bms 1
exit setup
Notes:
- Some BMS modules advertise intermittently.
- Multiple BLE scans may be required.
- Once a BMS address is configured, BMS telemetry reconnects directly using the saved address.
## Typical First-Time Setup Flow
log info
enter setup
scan ble
scan ble
select bms 1
relayname 1 Aux Power
relayname 2 Accessory Power
tempname 1 Cabin
tempname 2 Outside Air
save
config
## Known Notes
- DS18B20 sensors require a 4.7kΩ pull-up resistor on the 1-Wire data bus.
- The firmware uses generic relay and temperature IDs. Installation-specific names belong in saved configuration only.