2.8 KiB
2.8 KiB
ESP32 API and Serial Commands
HTTP API
Base URL while connected to the ESP32 access point:
http://192.168.4.1
Status
GET /status
Returns full controller status, including battery/BMS telemetry, relay states, temperature sensor states, alarms, system info, and current configuration.
Relay states use generic IDs:
relay_1
relay_2
Temperature sensors use generic IDs:
temp_1 through temp_8
Relay Control API
GET /relay/relay_1/on
GET /relay/relay_1/off
GET /relay/relay_2/on
GET /relay/relay_2/off
Relay display names are configurable. Firmware and API clients should not assume what a relay controls.
Configuration API
GET /config
Returns saved configuration.
POST /config/device
Example:
{
"device_name": "Overland Controller"
}
POST /config/relay
Example:
{
"id": "relay_1",
"name": "Aux Power",
"enabled": true
}
POST /config/bms
Example:
{
"enabled": true,
"name": "House Battery",
"address": "aa:bb:cc:dd:ee:ff",
"address_type": "public"
}
POST /config/temp
Example:
{
"id": "temp_1",
"name": "Cabin",
"address": "",
"enabled": true
}
POST /config/factory-reset
Clears saved configuration and restores generic defaults.
Serial Monitor
Baud:
115200
Line ending:
Newline
Status and Config Commands
status
config
save
factory reset
Device Configuration Commands
devicename Overland Controller
Run save after changing the device name.
Log Level Commands
log quiet
log info
log debug
Relay Control Commands
relay 1 on
relay 1 off
relay 2 on
relay 2 off
Relay Configuration Commands
relayname 1 Aux Power
relayname 2 Accessory Power
Run save after changing names.
Temperature Sensor Configuration Commands
tempname 1 Cabin
tempname 2 Outside Air
Run save after changing names.
BMS Configuration Commands
bmsname House Battery
bmsaddr aa:bb:cc:dd:ee:ff
Run save after changing BMS config manually.
BMS Setup Mode Commands
enter setup
scan ble
select bms 1
exit setup
Notes:
- Some BMS modules advertise intermittently.
- Multiple BLE scans may be required.
- Once a BMS address is configured, BMS telemetry reconnects directly using the saved address.
Typical First-Time Setup Flow
log info
enter setup
scan ble
scan ble
select bms 1
relayname 1 Aux Power
relayname 2 Accessory Power
tempname 1 Cabin
tempname 2 Outside Air
save
config
Known Notes
- DS18B20 sensors require a 4.7kΩ pull-up resistor on the 1-Wire data bus.
- The firmware uses generic relay and temperature IDs. Installation-specific names belong in saved configuration only.