Document ESP32 API and serial commands
This commit is contained in:
@@ -0,0 +1,324 @@
|
||||
# ESP32 API and Serial Commands
|
||||
|
||||
## HTTP API
|
||||
|
||||
Base URL while connected to ESP32 AP:
|
||||
|
||||
http://192.168.4.1
|
||||
|
||||
---
|
||||
|
||||
## Status
|
||||
|
||||
### GET /status
|
||||
|
||||
Returns full controller status.
|
||||
|
||||
Example:
|
||||
|
||||
http://192.168.4.1/status
|
||||
|
||||
Includes:
|
||||
|
||||
- Battery/BMS telemetry
|
||||
- Cell voltages
|
||||
- Temperature readings
|
||||
- Sensor health
|
||||
- Relay states
|
||||
- Vehicle state
|
||||
- Network state
|
||||
- Alarm state
|
||||
- System info
|
||||
- Current configuration
|
||||
|
||||
---
|
||||
|
||||
## Relay Control
|
||||
|
||||
### GET /relay/starlink/on
|
||||
|
||||
Turns relay 1 on.
|
||||
|
||||
### GET /relay/starlink/off
|
||||
|
||||
Turns relay 1 off.
|
||||
|
||||
### GET /relay/fridge/on
|
||||
|
||||
Turns relay 2 on.
|
||||
|
||||
### GET /relay/fridge/off
|
||||
|
||||
Turns relay 2 off.
|
||||
|
||||
Current legacy names:
|
||||
|
||||
- starlink = relay 1 / GPIO16
|
||||
- fridge = relay 2 / GPIO17
|
||||
|
||||
Future goal:
|
||||
|
||||
- Replace legacy names with generic relay IDs.
|
||||
|
||||
---
|
||||
|
||||
## Configuration API
|
||||
|
||||
### GET /config
|
||||
|
||||
Returns saved configuration.
|
||||
|
||||
Example:
|
||||
|
||||
http://192.168.4.1/config
|
||||
|
||||
---
|
||||
|
||||
### POST /config/relay
|
||||
|
||||
Updates relay config.
|
||||
|
||||
Example body:
|
||||
|
||||
{
|
||||
"id": "relay_1",
|
||||
"name": "Starlink",
|
||||
"enabled": true
|
||||
}
|
||||
|
||||
Valid IDs:
|
||||
|
||||
- relay_1
|
||||
- relay_2
|
||||
|
||||
---
|
||||
|
||||
### POST /config/bms
|
||||
|
||||
Updates BMS config.
|
||||
|
||||
Example body:
|
||||
|
||||
{
|
||||
"enabled": true,
|
||||
"name": "Greta",
|
||||
"address": "a5:c2:37:2c:05:dc",
|
||||
"address_type": "public"
|
||||
}
|
||||
|
||||
---
|
||||
|
||||
### POST /config/temp
|
||||
|
||||
Updates temperature sensor config.
|
||||
|
||||
Example body:
|
||||
|
||||
{
|
||||
"id": "temp_1",
|
||||
"name": "Fridge Zone 1",
|
||||
"address": "",
|
||||
"enabled": true
|
||||
}
|
||||
|
||||
Valid IDs:
|
||||
|
||||
- temp_1
|
||||
- temp_2
|
||||
- temp_3
|
||||
- temp_4
|
||||
- temp_5
|
||||
- temp_6
|
||||
- temp_7
|
||||
- temp_8
|
||||
|
||||
---
|
||||
|
||||
### POST /config/factory-reset
|
||||
|
||||
Clears saved config and restores defaults.
|
||||
|
||||
---
|
||||
|
||||
## Serial Monitor Commands
|
||||
|
||||
Serial baud:
|
||||
|
||||
115200
|
||||
|
||||
Line ending:
|
||||
|
||||
Newline
|
||||
|
||||
---
|
||||
|
||||
## Status and Config
|
||||
|
||||
### status
|
||||
|
||||
Prints full JSON status to Serial.
|
||||
|
||||
### config
|
||||
|
||||
Prints current configuration to Serial.
|
||||
|
||||
### save
|
||||
|
||||
Saves current in-memory configuration to NVS.
|
||||
|
||||
### factory reset
|
||||
|
||||
Clears saved config and restores defaults.
|
||||
|
||||
---
|
||||
|
||||
## Log Level
|
||||
|
||||
### log quiet
|
||||
|
||||
Minimizes serial output.
|
||||
|
||||
### log info
|
||||
|
||||
Normal serial output.
|
||||
|
||||
### log debug
|
||||
|
||||
Enables recurring debug output such as BMS and sensor updates.
|
||||
|
||||
---
|
||||
|
||||
## Relay Control
|
||||
|
||||
### relay starlink on
|
||||
|
||||
Turns legacy Starlink relay on.
|
||||
|
||||
### relay starlink off
|
||||
|
||||
Turns legacy Starlink relay off.
|
||||
|
||||
### relay fridge on
|
||||
|
||||
Turns legacy Fridge relay on.
|
||||
|
||||
### relay fridge off
|
||||
|
||||
Turns legacy Fridge relay off.
|
||||
|
||||
---
|
||||
|
||||
## Relay Configuration
|
||||
|
||||
### relayname 1 Starlink
|
||||
|
||||
Sets relay 1 display name.
|
||||
|
||||
### relayname 2 Fridge
|
||||
|
||||
Sets relay 2 display name.
|
||||
|
||||
Run `save` after changing names.
|
||||
|
||||
---
|
||||
|
||||
## Temperature Sensor Configuration
|
||||
|
||||
### tempname 1 Fridge Zone 1
|
||||
|
||||
Sets temp sensor 1 display name.
|
||||
|
||||
### tempname 2 Fridge Zone 2
|
||||
|
||||
Sets temp sensor 2 display name.
|
||||
|
||||
### tempname 3 Rear Seat Area
|
||||
|
||||
Sets temp sensor 3 display name.
|
||||
|
||||
### tempname 4 Outside Air
|
||||
|
||||
Sets temp sensor 4 display name.
|
||||
|
||||
Run `save` after changing names.
|
||||
|
||||
---
|
||||
|
||||
## BMS Configuration
|
||||
|
||||
### bmsname Greta
|
||||
|
||||
Sets BMS display name.
|
||||
|
||||
### bmsaddr a5:c2:37:2c:05:dc
|
||||
|
||||
Sets BMS BLE address.
|
||||
|
||||
Run `save` after changing BMS config manually.
|
||||
|
||||
---
|
||||
|
||||
## BMS Setup Mode
|
||||
|
||||
### enter setup
|
||||
|
||||
Enters BMS setup mode.
|
||||
|
||||
Effects:
|
||||
|
||||
- Disconnects BMS client
|
||||
- Pauses BMS reconnect
|
||||
- Allows repeated BLE scans
|
||||
|
||||
### scan ble
|
||||
|
||||
Scans for BLE devices.
|
||||
|
||||
Notes:
|
||||
|
||||
- JBD/Xiaoxiang BMS advertising can be intermittent.
|
||||
- Multiple scans may be required.
|
||||
- Greta may not appear every scan.
|
||||
|
||||
### select bms 1
|
||||
|
||||
Selects BLE scan result 1 as the configured BMS.
|
||||
|
||||
This saves:
|
||||
|
||||
- BMS name
|
||||
- BMS address
|
||||
- BMS enabled state
|
||||
|
||||
### exit setup
|
||||
|
||||
Leaves BMS setup mode and allows BMS reconnect.
|
||||
|
||||
---
|
||||
|
||||
## Typical First-Time Setup Flow
|
||||
|
||||
log info
|
||||
enter setup
|
||||
scan ble
|
||||
scan ble
|
||||
scan ble
|
||||
select bms 1
|
||||
relayname 1 Starlink
|
||||
relayname 2 Fridge
|
||||
tempname 1 Fridge Zone 1
|
||||
tempname 2 Fridge Zone 2
|
||||
tempname 3 Rear Seat Area
|
||||
tempname 4 Outside Air
|
||||
save
|
||||
config
|
||||
|
||||
---
|
||||
|
||||
## Known Notes
|
||||
|
||||
- BMS telemetry works reliably once the address is configured.
|
||||
- BLE scan works, but JBD/Xiaoxiang advertising is intermittent.
|
||||
- DS18B20 sensors require a 4.7kΩ pull-up resistor on the 1-Wire data bus.
|
||||
- Relay API still uses legacy names internally.
|
||||
- Future work should move relay runtime commands to generic relay IDs.
|
||||