Document JBD cell voltage bring-up
This commit is contained in:
@@ -467,3 +467,35 @@ Verified:
|
|||||||
- Subsequent reads succeed consistently.
|
- Subsequent reads succeed consistently.
|
||||||
- Current implementation reads basic pack telemetry only.
|
- Current implementation reads basic pack telemetry only.
|
||||||
- Cell voltage and cell delta support will require an additional JBD command.
|
- Cell voltage and cell delta support will require an additional JBD command.
|
||||||
|
|
||||||
|
## JBD Cell Voltage Bring-Up Results
|
||||||
|
|
||||||
|
### Date
|
||||||
|
|
||||||
|
2026-06-04
|
||||||
|
|
||||||
|
### Status
|
||||||
|
|
||||||
|
PASS
|
||||||
|
|
||||||
|
### Verified
|
||||||
|
|
||||||
|
- JBD cell voltage command works
|
||||||
|
- ESP32 receives cell voltage packet
|
||||||
|
- Firmware parses 4 cell voltages
|
||||||
|
- Firmware calculates min cell voltage
|
||||||
|
- Firmware calculates max cell voltage
|
||||||
|
- Firmware calculates cell delta
|
||||||
|
|
||||||
|
### Observed Values
|
||||||
|
|
||||||
|
- Cell count: 4
|
||||||
|
- Minimum cell voltage: 3.336V
|
||||||
|
- Maximum cell voltage: 3.337V
|
||||||
|
- Cell delta: 1mV
|
||||||
|
|
||||||
|
### Notes
|
||||||
|
|
||||||
|
- Pack appears well balanced.
|
||||||
|
- First BMS status read after boot may timeout, but subsequent reads succeed.
|
||||||
|