# ESP32 API and Serial Commands
|
||||
|
||||
## HTTP API
|
||||
|
||||
Base URL while connected to the ESP32 access point:
|
||||
|
||||
http://192.168.4.1
|
||||
|
||||
## Status
|
||||
|
||||
### GET /status
|
||||
|
||||
Returns full controller status, including battery/BMS telemetry, relay states, temperature sensor states, alarms, system info, and current configuration.
|
||||
|
||||
Relay states use generic IDs:
|
||||
|
||||
relay_1
|
||||
relay_2
|
||||
|
||||
Temperature sensors use generic IDs:
|
||||
|
||||
temp_1 through temp_8
|
||||
|
||||
## Relay Control API
|
||||
|
||||
GET /relay/relay_1/on
|
||||
GET /relay/relay_1/off
|
||||
GET /relay/relay_2/on
|
||||
GET /relay/relay_2/off
|
||||
|
||||
Relay display names are configurable. Firmware and API clients should not assume what a relay controls.
|
||||
|
||||
## Configuration API
|
||||
|
||||
### GET /config
|
||||
|
||||
Returns saved configuration.
|
||||
|
||||
### POST /config/device
|
||||
|
||||
Example:
|
||||
|
||||
{
|
||||
"device_name": "Overland Controller"
|
||||
}
|
||||
|
||||
### POST /config/relay
|
||||
|
||||
Example:
|
||||
|
||||
{
|
||||
"id": "relay_1",
|
||||
"name": "Aux Power",
|
||||
"enabled": true
|
||||
}
|
||||
|
||||
### POST /config/bms
|
||||
|
||||
Example:
|
||||
|
||||
{
|
||||
"enabled": true,
|
||||
"name": "House Battery",
|
||||
"address": "aa:bb:cc:dd:ee:ff",
|
||||
"address_type": "public"
|
||||
}
|
||||
|
||||
### POST /config/temp
|
||||
|
||||
Example:
|
||||
|
||||
{
|
||||
"id": "temp_1",
|
||||
"name": "Cabin",
|
||||
"address": "",
|
||||
"enabled": true
|
||||
}
|
||||
|
||||
### POST /config/factory-reset
|
||||
|
||||
Clears saved configuration and restores generic defaults.
|
||||
|
||||
## Serial Monitor
|
||||
|
||||
Baud:
|
||||
|
||||
115200
|
||||
|
||||
Line ending:
|
||||
|
||||
Newline
|
||||
|
||||
## Status and Config Commands
|
||||
|
||||
status
|
||||
config
|
||||
save
|
||||
factory reset
|
||||
|
||||
## Device Configuration Commands
|
||||
|
||||
devicename Overland Controller
|
||||
|
||||
Run `save` after changing the device name.
|
||||
|
||||
## Log Level Commands
|
||||
|
||||
log quiet
|
||||
log info
|
||||
log debug
|
||||
|
||||
## Relay Control Commands
|
||||
|
||||
relay 1 on
|
||||
relay 1 off
|
||||
relay 2 on
|
||||
relay 2 off
|
||||
|
||||
## Relay Configuration Commands
|
||||
|
||||
relayname 1 Aux Power
|
||||
relayname 2 Accessory Power
|
||||
|
||||
Run `save` after changing names.
|
||||
|
||||
## Temperature Sensor Configuration Commands
|
||||
|
||||
tempname 1 Cabin
|
||||
tempname 2 Outside Air
|
||||
|
||||
Run `save` after changing names.
|
||||
|
||||
## BMS Configuration Commands
|
||||
|
||||
bmsname House Battery
|
||||
bmsaddr aa:bb:cc:dd:ee:ff
|
||||
|
||||
Run `save` after changing BMS config manually.
|
||||
|
||||
## BMS Setup Mode Commands
|
||||
|
||||
enter setup
|
||||
scan ble
|
||||
select bms 1
|
||||
exit setup
|
||||
|
||||
Notes:
|
||||
|
||||
- Some BMS modules advertise intermittently.
|
||||
- Multiple BLE scans may be required.
|
||||
- Once a BMS address is configured, BMS telemetry reconnects directly using the saved address.
|
||||
|
||||
## Typical First-Time Setup Flow
|
||||
|
||||
log info
|
||||
enter setup
|
||||
scan ble
|
||||
scan ble
|
||||
select bms 1
|
||||
relayname 1 Aux Power
|
||||
relayname 2 Accessory Power
|
||||
tempname 1 Cabin
|
||||
tempname 2 Outside Air
|
||||
save
|
||||
config
|
||||
|
||||
## Known Notes
|
||||
|
||||
- DS18B20 sensors require a 4.7kΩ pull-up resistor on the 1-Wire data bus.
|
||||
- The firmware uses generic relay and temperature IDs. Installation-specific names belong in saved configuration only.
|
||||